Additel 160A 01

logo Additel

Description Additel 221A

Multifunction Temperature Calibrator

  • Sourcing, simulating and measuring, temperature and electrical signals
  • Smartphone-like menu and interface make the operation simpler and easier
  • The internal cold junction compensation sensor can be re-calibrated at ice point by users
  • Ultra-compact, 3.9” x 7.6” x 2.0”, and 1.6 lb (0.7 kg)
  • ISO 17025-accredited calibration w/data included


  • A highly integrated Multifunction Temperature Calibrator featuring several patented technologies, the 221A is an ultra-compact, rugged, and easy to use hand-held device for sourcing, simulating and measuring temperature, and electrical signals. Its smartphone-like menu and interface make the operation simpler and easier. The 221A is ideal for calibrating, maintaining, and troubleshooting process instrumentations. Automation and documentation capabilities make the 221A a turnkey solution.

  • The ADT221A multifunction temperature calibrator is a process tool for measuring, sourcing and simulating mA, mV, V, RTDs, thermocouples, ohms, frequency, and pulses, captures switch values and provides 24 V loop power.

    • Electrical
    Resistance measurement / simulation
    Voltage measurement / generation
    Current measurement /generation
    Frequency measurement / generation
    Pulse counting/generation
    24 VDC loop supply
    Switch sensing

    • Temperature RTD measurement /simulation
    TC measurement /simulation

    • Electrical Specifications

  • Measurement Accuracy

    Range Resolution Accuracy
    Voltage DC ±75.0000 mV 0.1μV 0.01%RD + 3.75 μV
    ±30.0000 V 0.1 mV 0.01%RD + 1.5 mV
    Current DC ± 30.0000 mA 0.1μA 0.01%RD + 1.5 μA
    Resistance Two-wire 0 to 400.000 Ω 1mΩ 0.02%RD + 0.02 Ω
    Three-wire 0 to 400.000 Ω 1mΩ 0.02%RD + 0.02 Ω
    Four-wire 0 to 400.000 Ω 1mΩ 0.01%RD + 0.02 Ω
    Two-wire 0 to 4000.00 Ω 10mΩ 0.02%RD + 0.2 Ω
    Three-wire 0 to 4000.00 Ω 10mΩ 0.02%RD + 0.2 Ω
    Four-wire 0 to 4000.00 Ω 10mΩ 0.01%RD + 0.2 Ω
    Frequency 1 to 50000.0 Hz 0.1Hz 0.005%RD + 1 Hz
    Pulse 0 to 999999 1 N/A
    Limit Switch For the contact with potential, the voltage within the range 3V to 24V.
    Source Accuracy
    Voltage DC -10.000 to 75.000mV 1μV 0.02%RD + 4.25 μV

    0 to 12.0000 V 0.1mV 0.02%RD + 0.6 mV
    Current DC 0 to 22.000 mA 1μA 0.02%RD + 1.1 μA
    Resistance 1 to 400.00 Ω 10mΩ 0.02%RD + 0.02 Ω

    1 to 4000.0 Ω 100mΩ 0.03%RD + 0.4 Ω
    Frequency 0 to 50000.0 Hz 0.1Hz 0.005%RD + 1 Hz
    Pulse 0 to 999999 1 N/A
    DC24V N/A N/A 0.5V
    Thermocouple Measurement and Source Accuracy
    Measure and Simulate Standard Temperature Range (oC) Accuracy (oC)
    Measure Source
    S IEC 584 -50 to 1768 -50 to400 1 1.1
    400 to 1000 0.6 0.6
    1000 to1768 0.7 0.8
    R IEC 584 -50 to 1768 -50 to 200 1.4 1.4
    200 to 500 0.6 0.6
    500 to 1768 0.6 0.7
    B IEC 584 0 to 1820 50 to 450 3.8 3.8
    450 to 800 0.9 0.9
    800 to 1820 0.6 0.7
    K IEC 584 -270 to 1372 -250 to -200 1 1.1
    -200 to -100 0.4 0.5
    -100 to 600 0.3 0.3
    600 to 1372 0.4 0.5
    N IEC 584 -270 to 1300 -250 to -200 1.5 1.6
    -200 to -100 0.5 0.6
    -100 to 1300 0.4 0.5
    E IEC 584 -270 to 1000 -250 to -200 0.6 0.7
    -200 to -100 0.3 0.3
    -100 to 0 0.2 0.2
    0 to 700 0.2 0.3
    700 to 1000 0.2 0.4
    J IEC 584 -270 to 1200 -210 to -100 0.3 0.3
    -100 to 1200 0.3 0.4
    T IEC 584 -270 to 400 -250 to -200 0.8 0.9
    -200 to 0 0.4 0.4
    0 to 400 0.2 0.2
    C ASTM E988 0 to 2315 0 to 1000 0.5 0.5
    1000 to 1800 0.7 0.9
    1800 to 2315 1 1.4
    D ASTM E988 0 to 2320 0 to 100 0.5 0.5
    100 to 1100 0.4 0.5
    1100 to 2000 0.6 0.9
    2000 to 2320 0.9 1.3
    G ASTM E1751 0 to 2315 0 to 200 2.4 2.4
    200 to 400 0.5 0.5
    400 to 1400 0.4 0.5
    1400 to 2315 0.7 1
    L DIN43710 -200 to 900 -200 to -100 0.2 0.3
    -100 to 400 0.2 0.2
    400 to 900 0.2 0.3
    U DIN43710 -200 to 600 -200 to 0 0.4 0.4
    0 to 600 0.2 0.3
    *Accuracy with external cold junction; for internal cold junction add 0.1°C (k=2)
    Measurement Accuracy
    Measure and Simulate Standard Temperature Range (°C) Accuracy (°C)
    Measure (2W/3W) Measure (4W) Source
    Pt10(385) IEC 751 -200 to 850 -100 to 200 0.65 0.6 0.65
    200 to 600 0.82 0.72 0.82
    600 to 850 0.96 0.82 0.96
    Pt100(385) IEC 751 -200 to 850 -100 to 200 0.15 0.1 0.15
    200 to 600 0.26 0.16 0.26
    600 to 850 0.34 0.2 0.34
    Pt100(3916) JIS 1604 -200 to 850 -100 to 200 0.15 0.1 0.15
    200 to 600 0.26 0.16 0.26
    600 to 850 0.33 0.2 0.33
    Pt100(3926) Minco Application Aid #18 -200 to 850 -100 to 200 0.15 0.1 0.15
    200 to 600 0.26 0.16 0.26
    600 to 850 0.33 0.2 0.33
    Pt500(385) IEC 751 -200 to 850 -100 to 200 0.2 0.16 0.36
    200 to 600 0.32 0.22 0.54
    600 to 850 0.4 0.27 0.67
    Pt1000(385) IEC 751 -200 to 850 -100 to 200 0.1 0.05 0.25
    200 to 600 0.2 0.1 0.42
    600 to 850 0.27 0.14 0.54
    Cu10(427) Minco Application Aid #18 -100 to 260 -100 to 260 0.61 0.56 0.61
    Cu50(428) GOST 6651-94 -50 to 150 -50 to 150 0.17 0.13 0.17
    Cu100(428) GOST 6651-94 -50 to 150 -50 to 150 0.12 0.09 0.12
    Ni120(672) Edison curve #7 -100 to 260 -100 to 260 0.07 0.05 0.07
    Ni100(618) DIN 43760 -100 to 260 -100 to 260 0.08 0.06 0.08
    General Specifications
    Operating Temperature-10°C to 50°C
    Storage Temperature-20°C to 60°C
    Humidity<90%, non-condensing
    European ComplianceCE Mark
    Protection LevelIP30
    Display3.5 inch TFT color screen
    Electrical ConnectionØ4mm sockets and flat mini-jack thermocouple socket
    RS232 InterfaceStandard RS232-DB9 socket
    Size3.9" x 7.6" x 2.0" (100mm x 192mm x 52mm)
    Weight1.6 lb (0.7 kg)
    Power SupplyPolymer Li-ion rechargeable battery,or 10V DC adaptor
    BatteryRechargeable Li-ion battery (included)
    Battery Life15 hours uninterrupted use
    Battery life will be reduced when 24V is applied
    Battery Charge110V/220V external power adapter (included)